Parcel ID 00532701030700 Owner CONDE ORLANDO
Unit Owner Address 2801 NW 7TH STREET
Property Address 30 PIGEON DR City/State/Zip MIAMI , FL 33125
City/State/Zip KEY LARGO , FL 33037
CASE DESCRIPTION
COMPLAINANT STATES VIA EMAIL:
"IN FEAR OF REPERCUSSION I CHOOSE TO STAY
ANONYMOUS REGARDING THIS CONCERN. I CURRENTLY LIVE
ACROSS THE CANAL OF 30 PIGEON DRIVE (SEXTON COVE
ESTATE), KEY LARGO WHICH IS THE ADDRESS OF MY
CONCERN. THE OWNERS OF SUCH PROPERTY APPEARED TO
HAVE CONSTRUCTED A HUGH STRUCTURE ROUND THEIR
EXISTING MOBILE HOME WHICH I FEAR IS NOT WITHIN
CODE AND IN THE EVENT OF A WINDSTORM IT CAN CAUSE
SUBSTANTIAL DAMAGE TO THE SURROUNDING HOME
INCLUDING MINE. I FOUND IT ODD THAT MOST OF THE
CONSTRUCTION WAS DONE ON WEEKENDS WHICH GIVES ME
REASON TO BELIEVE THAT THEY WERE CONCEALING THE
CONSTRUCTION AND OBSCURE FROM BEING DETECTED BY
BUILDING OR CODE INSPECTORS. ADDITIONALLY, I’VE
ALSO NOTICED THEY INSTALLED A JACUZZI NEAR THE
CANAL AND I HOPE NONE OF THE CHEMICALS THEY USED
FOR MAINTENANCE HAS BEEN DISCHARGED INTO THE
CANAL."
NOTES
04-12-2013 11:33:12 am
INITIAL SITE VISIT ON 4/8/13 SHOWS MOBILE HOME WITH
ADDITION(S). APPEARS TO BE STUCCO AND WINDOWS. THE HOT
TUB (JACUZZI) IS SITTING ON WHAT USED TO BE THE BOAT
RAMP, WHICH IS NOW GONE. WILL RESEARCH PERMIT HISTORY
AND ARCHIVE PHOTOS FROM PROPERTY APPRAISER'S OFFICE
08-20-2013 04:02:46 pm
MEETING WITH THE PROPERTY OWNER/S IN REFERENCE TO
CLARIFY WHAT IS PERMITTABLE AND WHAT IS PROHIBITED. THE
MEETING WAS HELD WITH CODE, FLOOD, BUILDING AND THE
PLANNING DEPARTMENT STAFF. THE DETERMINATION BY FLOOD
IS AS FOLLOW:
THIS PROPERTY IS LOCATED IN AN AE 10 SPECIAL FLOOD
HAZARD AREA. THE TRAILER WAS PERMITTED PRIOR TO 1975 SO
IT WOULD BE CONSIDERED PRE-FIRM AND WOULD FALL UNDER
THE NON SUBSTANTIAL IMPROVEMENT RULE(50%). HOWEVER ANY
ADDITION TO THE TRAILER WOULD HAVE TO BE FOURTH WALL
CONSTRUCTION(STAND-ALONE) AND WOULD BE REQUIRED TO MEET
ALL CURRENT CODES. ANYTHING THAT WAS ADDED WITHOUT A
PERMIT OR INSPECTIONS CANNOT BE CONSIDERED
NON-CONFORMING(GRANDFATHERED) AS IT IS ILLEGAL . I DO
NOT HAVE AN ELEVATION CERTIFICATE FOR THIS EXACT
PROPERTY SO AS TO DETERMINE THE ELEVATION OF THE
FINISHED FLOOR. I HAVE ONE FOR SEVERAL LOTS DOWN AND
GRADE IS AROUND 4.0 TO 4.5 FEET NGVD. THIS WOULD PUT
THIS PROPERTY AROUND 5 ½ TO 6 FEET BELOW BASE FLOOD. AT
THIS POINT THE OPTIONS FOR COMPLIANCE WITH THE FLOOD
ORDINANCE WOULD BE TO APPLY FOR A PERMIT(DEMOLITION) TO
RETURN THE AREA BACK TO THE CARPORT THAT WAS LEGALLY
PERMITTED OR TO APPLY FOR A PERMIT TO ELEVATE THE
ADDITION TO ABOVE BASE FLOOD ELEVATION OF 10 FOOT
NGVD. FOLLOWING THIS DETERMINATION CODE HAS GIVEN THE
PROPERTY OWNER/S UNTIL 10-01-2013 TO SUBMIT SOME TYPE
OF PERMIT APPLICATION, WHETHER IT'S FOR DEMOLITION
AND/OR ENGINEERING PLANS FOR CONSTRUCTION TO REBUILD.
PROPERTY OWNER/S AGREED.
10-16-2013 01:07:26 pm
MEETING WITH THE CONTRACTOR AND PROPERTY OWNER/S WHICH
INCLUDED CODE AND FLOOD (B. CORCORAN). THE MEETING WAS
JUST A CONFIRMATION OF TURNING THE ADDITION INTO A
STORAGE SPACE. ALL PARTIES AGREED AND THE CONTRACTOR
WILL BE SUBMIT THE PERMIT IN THE NEXT 10 DAYS OR
SOONER.
INSPECTIONS / EVENTS DETAILS
DATE INSPECTION/EVENT TYPE INSTRUCTIONS/COMMENTS
01-25-2018 CLOSE CASE EVENT

01-25-2018 REINSPECTION

DEMO PERMIT HAS NOW BEEN INSPECTED AND

CLOSED- THIS CASE IS IN COMPLIANCE- CASE

CLOSED- LC

11-16-2017 REINSPECTION

DEMO PERMIT#17304151 HAS BEEN

ISSUED-CASE TO BE CLOSED ONCE PERMIT IS

INSPECTED AND CLOSED- LC

08-22-2017 REINSPECTION

BOTH DEMO PERMIT#17304151 AND SFR

PERMIT#16308419 ARE READY FOR PICK UP-

LC

04-21-2017 REINSPECTION

SFR PERMIT WTILL GOING THROUGH REVIEW-LC

01-23-2017 REINSPECTION

A PERMIT FOR NEW SFR HAS BEEN A APPLIED

FOR 16306684 WHICH WILL SATISFY THIS

CODE CASE. LC

07-14-2016 REINSPECTION

180 DAY EXT HAS BEEN GRANTED- PASSED

INSPECTION MUST BE COMPLETED PRIOR TO

12/21/2016-LC

12-14-2015 REINSPECTION

PERMIT#15301460 IN FINAL REVIEW

STAGE-HAS BEEN APPROVED BY ALL DEPTS-

FOLLOW UP ACCORDINGLY- LC

08-14-2015 REINSPECTION

MEETING WITH THE CONTRACTOR, PROPERTY

OWNERS, BIO (CHRIS) AND FLOOD

(JENNIFER). CONTRACTOR WAS ADVISED ON

WHAT CORRECTIONS/REVISIONS NEED TO BE

MADE ON THE SITE PLAN. CODE AND

CONTRACTOR ADVISED THE PROPERTY OWNERS

THAT THE 4 CORNERS OF THE ADDITION NEEDS

TO BE REMOVED IN ORDER TO VERIFY THE 4TH

WALL CONSTRUCTION. CONTRACTOR WILL STAY

IN COMMUNICATION WITH THE REASSIGNED

CODE INSPECTOR. NOTE: DUE TO A FAMILY

EMERGENCY THE PROPERTY OWNERS WILL BE

OUT OF TOWN FOR ABOUT 30 DAYS.

07-30-2015 REASSIGN INSPECTOR

REASSIGNED INSPECTOR FROM WRR TO LC PER

SUPERVISOR’S REQUEST-B.RIGBY

07-16-2015 REINSPECTION

REVIEWED PERMIT 15301460 FOR APPROVAL.

PREVIOUS PERMIT 13304710 HAS BEEN

VOIDED. SUBMITTED DIAGRAM AND PHOTOS IN

PERMIT AND FORWARDED PERMIT TO THE

BUILDING DEPARTMENT. ADVISED THE

CONTRACTOR OF THE UPDATE AND WHAT

CHANGES NEED TO BE MADE. AS PER THE

BUILDING STAFF THE PERMIT HAS BEEN

PLACED IN THE PENDING DRAW.

06-15-2015 REINSPECTION

CODE CONDUCTED A SITE INSPECTION AND TO

MEASUREMENTS AS PER THE BIOLOGISTS

REQUEST. THE PROPERTY OWNER HAS COMPLIED

WITHTHE PREVIOUS BUILDING OFFICIAL,

FLOOD PLAIN INSPECTOR, AND PLANNING.

THERE APPEARS TO BE SOME CONFUSION ON

WHAT WAS AGREED UPON TO BE IN

COMPLIANCE. CODE WILL FORWARD ALL

INFORMATION TO THE CURRENT BUILDING

OFFICIAL AND BIO.

06-08-2015 REINSPECTION

PROPERTY OWNERS CAME IN TO DISCUSS THE

PERMIT AND PROVIDE CODE WITH AN UPDATE.

CONTRACTOR AND PROPERTY OWNER STATED

THAT ALTHOUGH THERE WAS A MEETING HELD

RECENTLY WITH FLOOD AND BIO. THERE IS

SOME CONFUSION ON WHAT IS ON SITE AND

SETBACK. EXISTING AND NOT EXISTING AND

4TH WALL. CODE IS SCHEDULED TO CONDUCT A

SITE INSPECTION AND MEET WITH THE

PROPERTY OWNERS AND CONTRACTOR.

04-29-2015 REINSPECTION

PROPERTY OWNER AND CONTRACTOR CAME IN TO

ADVISE CODE THAT ADDITIONAL REVISIONS

NEED TO BE SUBMITTED BUT THE PERMIT

SHOULD BE APPROVED AND ISSUED ONCE THE

REVISIONS ARE SUBMITTED. CONTRACTOR WILL

KEEP CONTINOUS COMMUNICATIONS WITH THE

CODE DEPARTMENT

03-20-2015 REINSPECTION

CONTRACTOR CAME IN TO ADVISE CODE THAT

THE BUILDING DEPARTMENT EXPIRED THE

PREVIOUS PERMIT. CONTRACTOR SUBMITTED A

NEW PERMIT 15301460 TO INCLUDE THE

SWALE. PENDING APPROVAL

12-11-2014 REINSPECTION

CONTRACTOR CAME IN AND PROVIDED CODE

COMPLIANCE WITH AN UPDATE. CONTRACTOR

WILL BE SUBMITTING A NEW APPILCATION FOR

REVISIONS ON THE CURRENT PERMIT.

11-25-2014 REINSPECTION

SENT NOTICE/LETTER TO THE PROPERTY OWNER

TO CHECK THE STATUS OF THE PERMIT.

03-26-2014 REINSPECTION

PERMIT STILL UNDER REVIEW..

01-28-2014 COMMENT CODE

PERMIT IS STILL UNDER REVIEW. PENDING

APPROVAL

11-26-2013 COMMENT CODE

PERMIT CE13050080 APPLIED FOR.-B.RIGBY

11-26-2013 COMMENT CODE

PERMIT 13304710 APPLIED FOR. PASSED TO

INSPECTOR.-B.RIGBY

11-22-2013 COMMENT CODE

CONTRACTOR CAME IN TO ADVISE THAT HE

SUBMITTED THE PERMIT 13304710 FOR

REVIEW.

10-09-2013 REINSPECTION

MEETING WITH THE CONTRACTOR AND PROPERTY

OWNER TO VERIFY PERMIT PLANS.

08-16-2013 COMMENT CODE

MEETING WITH THE PROPERTY OWNER/S, CODE,

FLOOD, BUILDING AND PLANNING DEPARTMENT

STAFF. SEE NOTES AND ATTACHED DOCUMENTS

08-16-2013 REASSIGN INSPECTOR

REASSIGNED INSPECTOR FROM DCL TO WRR

PER SUPERVISOR’S REQUEST-B.RIGBY

08-09-2013 COURTESY NOV/LTR

PREPARED WRITTEN WARNING FOR MAILING AND

SENT TO MARATHON TO BE MAILED. –B.RIGBY

07-02-2013 COMMENT CODE

CASE FILE TO WWR TO REASSIGN AN

INSPECTOR

04-08-2013 INITIAL INSPECTION TYPE

SCREEN PORCH ENCLOSED WITH WALL &

WINDOWS -

04-04-2013 CREATE A CASE

COMPLAINT RECORDED BY RIGBYB