Case Number | CE11040042 | ||
---|---|---|---|
Case Date | 04-11-2011 | ||
Origination | 5 -REFERRAL | Status | CLOSED CASE |
Operator | walbroek | Officer | WINDSOR, KATHLEEN |
Parcel ID | 00529930000000 | Owner | GONZALEZ ATILIO AND JEANNETTE G |
---|---|---|---|
Unit | Owner Address | 46 WATERWAYS DR | |
Property Address | 46 WATERWAYS DR | City/State/Zip | KEY LARGO , FL 33037 |
City/State/Zip | KEY LARGO , FL 33037 |
FLOOD PLAIN INSPECTION |
1: FLOOD PLAIN MANAGEMENT |
2: FLOOD PLAIN MANAGEMENT |
1: 122-4.(b)(1)d - PERMIT CONDITIONS/FLOOD HAZARD |
06-03-2016 03:07:22 pm | |
CORRECTIVE ACTIONS PER FLOOD: | |
DEMO FOR FEMA COMPLIANCE FOR ENCLOSURE UNDER ELEVATED | |
HOUSE TO INCLUDE THE FOLLOWING: | |
1. DEMO ALL INTERIOR PARTITIONS, INCLUDING CLOSETS | |
AND | |
STUD WALLS | |
2. DEMO ALL PLUMBING, PIPES, WATERLINES, FIXTURES, | |
CABINETS, COUNTERS, APPLIANCES AND FURNITURE | |
3. DEMO ALL REMAINING WALL FINISH AT LEAST TO THE | |
BASE | |
FLOOD ELEVATION OF 9' NGVD WHICH IS 4.4' ABOVE THE | |
SLAB | |
4. DEMO WALL A/C UNIT AND REPAIR LOCATION | |
5. INSTALL A MINIMUM OF 864 NET SQUARE INCHES OF | |
FLOOD | |
VENTING. THERE MUST BE AT LEAST 2 VENTS AND ALL VENTS | |
CANNOT BE LOCATED | |
ON THE SAME WALL. THE BOTTOM OF THE VENTS CAN BE NO | |
HIGHER THAN 12" ABOVE GRADE. IF LOUVER COVERS ARE | |
APPLIED, ADDITIONAL VENTING COULD BE REQUIRED. | |
*****IN ADDITION TO THE REQUIRED BUILDING | |
INSPECTIONS, | |
A REINSPECTION IS REQUIRED FOR THE FLOOD INSURANCE | |
INSPECTION PROGRAM. DETAILED PHOTOS OF THIS | |
INSPECTION | |
MUST BE FOWARDED TO THE SR FLOODPLAIN COORDINATOR IN | |
MARATHON FOR FINAL APPROVAL AND PRIOR TO PERMIT | |
CLOSURE-MW |
DATE | INSPECTION/EVENT TYPE | INSTRUCTIONS/COMMENTS |
---|---|---|
07-05-2016 | CLOSE CASE EVENT |
EMAIL FROM MARY WINGATE, CASE IS COMPLIANT. CLOSEED CASE - KAT SEE COMPLIANCE PHOTOS IN PERMIT 16303721 . NOTHING TO SCAN. MW HAS FLOOD FILE. |
06-06-2016 | ACTION BY ADMIN |
RECEIVED PERMIT APPLICATION FROM MTH. LOGGED AND PASSED TO ELECTRIC.-B.RIGBY |
06-03-2016 | ACTION BY SR CC RES ANALYST |
FILE IN SHORT CABINET |
06-03-2016 | PERMIT APPLICATION REVIEW |
16303721 - DEMO FOR FEMA COMPLIANCE. PLAN REVIEW: **THIS PERMIT APPLICATION IS TO SATISFY CODE CASE CE11040042 FOR VIOLATIONS AS A RESULT OF A FLOOD INSURANCE INSPECTION. FINAL INSPECTIONS REQUIRED. COMPLIANCE WILL BE ACHIEVED WITH PERMIT ISSUANCE, COMPLETION OF ALL WORK, ALL REQUIRED INSPECTIONS HAVE PASSED AND PERMIT IS CLOSED. PROPERTY OWNER TO CONTACT INSPECTOR WINDSOR UPON COMPLETION OF ALL REQUIRED INSPECTIONS AND PERMIT IS CLOSED. KWINDSOR*** |
04-27-2016 | ACTIVITY BY SR DIRECTOR |
REC'D CALL FROM POTENTIAL NEW BUYER. REQUESTED INFORMATION REGARDING ACCRUING FINES. CJM |
07-15-2015 | COMMENT CODE |
REVIEW: SAME OWNERS NO LIS PENDENS |
07-15-2015 | MAKE VIOLATION |
MAKEVIO RECORDED WINDSORK |
09-26-2014 | COMMENT CODE |
REFERRAL FROM FLOODPLAIN ADMINISTRATOR |
04-12-2011 | FEMA SUBMIT TO RATE |
MEASUREMENTS AND PHOTOS TAKEN AND RETURNED TO MARY WINGATE ON 4-25-11 |
04-11-2011 | CREATE A CASE |
COMPLAINT RECORDED BY WALBROEK |